MIL-DTL-38449D
e. Immersion (leakage) (see 4.4.7.7).
TABLE III. Functional test.
Test
Control or Switch Positions
Observation 1/ 2/
Set power supply to 30 +0, -.5V dc
HIGH VOLTAGE
S5 in DC position
S6 in OFF position
1. READY
No switches activated
Lamps A, C, E, & H ON --
Condition
All others OFF
2. CONTACT
Momentarily close S1
Lamps A, D, H, I, & J ON --
Condition
All others OFF
3. DISCONNECT
Momentarily close S2
Lamps A, G, & I ON --
Connection
All others OFF
4. RESET
Momentarily open S3
Lamps A, C, E, & H ON --
All others OFF
5. FIRE THRU
Momentarily close S4
Lamps A, G, & I ON --
All others OFF
6. RESET
Momentarily close S3
Lamps A, C, E, & H ON --
All others OFF
7. SENSITIVITY
Set S5 to PULSE position and signal
(NO ADVANCE)
level control to 5.0 +0, -.1V (classes 1
and 2); 4.0 +0, -.1V (classes 3 and 4)
(a) Steady signal
Close S6 and reopen
Lamps A, C, E, & H remain
ON -- All others OFF
18